Release · worksheet · CSVtoCSA editorial

Validation Summary Worksheet

Version 2.0 · Updated 2026-09-21 · Release

Summarise completed testing, unresolved deviations, residual risks, and the conclusion supporting release.

Adapt this template to your intended use, applicable requirements, and approved procedures.

When to use it

Use before documenting the corresponding assessment or decision.

Information needed before starting

  • Approved intended use and functional-risk assessment
  • Available supplier and local evidence
  • Test environment, representative data and competent reviewers

Field instructions

  • Proposed use: Define the precise use proposed for release, including users, functions, environment and excluded actions.
  • Evaluated configuration: Identify the exact version and local settings covered by the evidence; explain differences from the proposed release configuration.
  • Acceptance basis: Reference approved requirements, risks and predefined acceptance criteria. Identify any changes and their justification.
  • Evidence reviewed: List the executed tests, supplier evidence and other reviewed records, including identifiers, versions and material limitations.
  • Unresolved issue: Identify each remaining deviation or evidence gap, its impact, owner and proposed restriction or follow-up.
  • Impact rationale: Explain why the remaining issue does or does not affect the proposed use, referencing controls and supporting evidence.
  • Decision: Record the supported use or restriction, the evidence and unresolved issues behind it, and the accountable decision owner.
  • Follow-up: Assign each unresolved finding or additional check to an owner and due date; state the completion evidence required.
  • Monitoring: State what will be compared or monitored, against which baseline, by whom and how often. Define discrepancy thresholds and the response.
  • Reassessment: Define changes, incidents, performance signals or dates that require review of the release conclusion.

Could the conclusion still be defended if the reviewer only had the linked evidence and this record? An approval signature cannot replace a missing technical basis.

Completed fictional example

Fictional teaching example; replace its values with your own assessed facts and evidence.

FieldCompleted example
Proposed useeQMS CAPA workflow with defined routing
Evaluated configurationRelease 8.4, route configuration RC-12
Acceptance basisApproved requirements, assessed failures, defined evidence plan
Evidence reviewedSupplier package, local tests, defect resolution, access checks, operating readiness
Unresolved issueDashboard spacing issue; no lost information or altered meaning in assessed views
Impact rationaleDoes not affect routing, approval, or required record content within the assessed scope
DecisionAuthorized use within the defined scope, subject to the organization’s approval process
Follow-upNamed owner and correction date in controlled issue record
MonitoringRouting exceptions and export issues
ReassessmentSupplier, configuration, process, or permission changes affecting the claims

Blank template

System / record ID: ____________________

Prepared by / date: ____________________

Required review / approval under local procedure: ____________________

FieldYour entry
Proposed use____________________
Evaluated configuration____________________
Acceptance basis____________________
Evidence reviewed____________________
Unresolved issue____________________
Impact rationale____________________
Decision____________________
Follow-up____________________
Monitoring____________________
Reassessment____________________
Relevant regulations and guidance

These sources apply within their stated scope. The suggested worksheet fields, test designs and fictional decisions are practitioner recommendations, unless a source requirement is expressly identified. Completing a template does not establish compliance.

Computer Software Assurance for Production and Quality Management System Software ↗

Regulatory guidance / GMP guideline · United States · February 2026

Scope: Medical-device manufacturers assuring software used in production or their quality management system.

Relevance: For medical-device production or QMS software, supports selecting assurance activities from intended use, risk and available evidence. It is nonbinding guidance and does not determine other sectors’ obligations.

Status: Final / published · Checked 2026-09-21

Publication identity, scope and status checked against the linked official source. This is not an independent audit of every retained guide statement.

Read source details and applicability →

EudraLex Volume 4, Annex 11 — Computerised Systems ↗

Regulatory guidance / GMP guideline · European Union · January 2011 revision

Scope: Computerised systems supporting activities in the applicable EU pharmaceutical GMP context.

Relevance: For computerised systems used in EU GMP activities, informs lifecycle, supplier and record controls. Confirm applicability to the actual activity; the example does not establish it.

Status: Final / published · Checked 2026-09-21

The Commission index confirms the January 2011 operative revision. The linked PDF could not be retrieved in this check; retained detailed section mappings need review against an authorized copy.

Read source details and applicability →
Was this useful? Leave feedback

Was this resource useful?

Was this template clear and useful? Tell us which instruction or field could be improved.

Loading contribution options…

Questions and moderated discussion

Questions and discussion

Ask a question or share a perspective. Contributions are reviewed before publication.

Loading contribution options…

Suggest a correction

Sent privately to the editorial moderation queue. Your account email and correction are not published as a comment. Do not include confidential or personal information.

Resource: Validation Summary Worksheet

Loading sign-in status…

Correction details